Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Dental press j. orthod. (Impr.) ; 17(4): 77-84, July-Aug. 2012. ilus, tab
Article in English | LILACS | ID: lil-653505

ABSTRACT

INTRODUCTION: Preserving the dental enamel structure during removal of orthodontic accessories is a clinician's obligation. Hence the search for an evidence based debonding protocol. OBJECTIVE: to evaluate and compare, by means of scanning electron microscopy (SEM), the effects of four different protocols of bracket debonding and subsequent polishing on enamel surface, and to propose a protocol that minimizes damage to enamel surface. METHODS: Twelve bovine permanent incisors were divided into four groups according to the instrument used for debonding and removal of the adhesive remnant. In groups 1 and 2, brackets were debonded with a straight debonding plier (Ormco Corp., Glendora, California, USA), and in groups 3 and 4, debonding was performed with the instrument Lift-Off (3M Unitek, Monrovia, California, USA). In groups 1 and 3, the adhesive remnant was removed using a long adhesive removing plier (Ormco Corp., Glendora, California, USA) and in groups 2 and 4, residual adhesive was removed with a tungsten carbide bur (Beavers Dental) at high-speed. After each stage of debonding and polishing, enamel surfaces were replicated and electron micrographs were obtained with 50 and 200X magnification. RESULTS: All four protocols of debonding and polishing caused enamel irregularities. CONCLUSION: Debonding brackets with straight debonding plier, removal of adhesive remnant with a tungsten carbide bur and polishing with pumice and rubber cup was found to be the protocol that caused less damage to enamel surface, therefore this protocol is suggested for debonding brackets.


INTRODUÇÃO: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. OBJETIVO: objetivou-se avaliar por microscopia eletrônica de varredura (MEV) a influência de quatro protocolos de remoção de braquetes e polimento da superfície do esmalte e propor um protocolo que minimize os danosà superfície do esmalte. MÉTODOS: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos braquetes e remoção do remanescente adesivo. Os braquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X. RESULTADOS: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do braquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos.

2.
Araçatuba; s.n; 2011. 63 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-710787

ABSTRACT

Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações


Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles


Subject(s)
Orthodontic Anchorage Procedures , Orthodontics , Torque
3.
Araçatuba; s.n; 2011. 63 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-705169

ABSTRACT

Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações.


Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles.


Subject(s)
Orthodontic Anchorage Procedures , Orthodontics , Torque
4.
Braz. oral res ; 23(4): 407-414, Oct.-Dec. 2009. ilus, graf, tab
Article in English | LILACS | ID: lil-534212

ABSTRACT

This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.


Subject(s)
Animals , Cattle , Aluminum Oxide/chemistry , Dental Bonding , Dental Cements/chemistry , In Vitro Techniques , Orthodontic Brackets , Shear Strength , Adhesiveness , Acrylic Resins/chemistry , Aluminum Silicates/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Dental Bonding/standards , Glass Ionomer Cements/chemistry , Materials Testing , Resin Cements/chemistry , Surface Properties , Stainless Steel/chemistry , Time Factors
5.
Rev. dent. press ortodon. ortopedi. facial ; 14(1): 117-123, jan.-fev. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-503885

ABSTRACT

OBJETIVO: avaliar o Índice de Remanescente Adesivo (IRA) em dentes bovinos após a descolagem de braquetes com e sem tratamento na base. METODOLOGIA: foram utilizados três sistemas de colagem ortodôntica para os dois padrões de base. Os dentes bovinos foram divididos em seis grupos de 40, de acordo com a base do braquete e o sistema de colagem. Vinte e quatro horas após a colagem foram realizados os testes de compressão em uma máquina de ensaios. A avaliação do IRA foi realizada em um estereomicroscópio por três examinadores calibrados. Foi utilizado o teste não paramétrico de Kruskal-Wallis, seguido do método de Dunn, para fazer as comparações múltiplas entre todos os grupos. RESULTADOS E CONCLUSÕES: observou-se que o tratamento das bases dos braquetes com óxido de alumínio não foi determinante para o aumento da adesividade entre o braquete e o adesivo. O grupo em que se utilizou braquetes com tratamento na base e adesivo TXT (3M-Unitek) + Transbond Plus SEP (3M-Unitek) apresentou a maior parte das fraturas na interface dente-adesivo (escore 4).


AIM: To assess the Adhesive Remnant Index (ARI) in bovine teeth after debonding mesh bases and sandblasted orthodontic bracket bases. METHODS: Were used three bonding systems for the two standards of base. The bovine teeth were divided into 6 groups of 40, according to the bracket base and to the bonding system. Twenty four hours after bonding they had been carried through shear bond strength tests in a universal testing machine. The assessment of ARI was performed in a stereomicroscopy by three calibrated examiners. It was used the non-parametric Kruskall-Wallis test, followed by Dunn's method, to do the multiple comparisons among all groups. RESULTS AND CONCLUSIONS: It was observed that the aluminum oxide sandblasting bracket bases was not determinative to the increase of the adhesiveness between bracket and adhesive. The group where it was used sandblasted orthodontic bracket bases and bonding system TXT (3M-Unitek) + Transbond Plus SEP (3M-Unitek) presented the majority of the failures at the teeth-adhesive interface (score 4).


Subject(s)
Cattle , Orthodontic Brackets , Dental Bonding , Dentin-Bonding Agents , In Vitro Techniques , Aluminum Oxide , Incisor , Materials Testing
6.
Ortodontia ; 40(2): 102-108, abr.-jun. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-542399

ABSTRACT

O objetivo do presente estudo consistiu em avaliar a relação entre a idade óssea determinada por meio das vértebras cervicais e o nível de desenvolvimento do canino e primeiro pré-molar inferiores esquerdos. A amostra constou de radiografias de 169 pacientes selecionados da clínica de Ortodontia da FOA-Unesp, sendo 106 do sexo feminino e 63 do sexo masculino. A idade dentária foi analisada em radiografias panorâmicas utilizando-se o sistema de classificação proposto por Nolla23 (1960) e a idade óssea, em telerradiografias em norma lateral pelo método de Baccetti et al2 (2002). Observou-se que nos estágios de maturação esquelética I e II, o canino inferior se apresentava no estágio 8 em 32% e 34,2% dos casos, respectivamente. Já o primeiro pré-molar inferior apresentava-se no estágio 7 em 30,7% dos casos e no estágio 8 em 39,5% dos pacientes nestes mesmos estágios de maturação. Quando o paciente se encontrava nos estágios de maturação esquelética III, IV e V, o canino atingira já o último grau de mineralização -estágio 10 de Nolla em 93,8%, 95,8% e 100% dos casos, respectivamente. O mesmo ocorreu para o pré-molar em 86,6%, 95,7% e 92,9% dos casos, respectivamente. Os resultados indicam que nos estágios mais tardios do crescimento e desenvolvimento humano, o nível de formação de caninos e primeiros pré-molares inferiores se encontra igualmente mais adiantado. Desta forma, houve uma associação entre o nível de desenvolvimento destes dentes e o estágio de maturação determinado pelas vértebras cervicais na amostra estudada.


The aim of the present study consists to assess the relation between the bone age determined by cervical vertebrae and the level of canine and lower left first premolar development. The sample consist in x-ray of 169 patient selected in Orthodontic Clinic of FOA - Unesp, were 106 girls and 63 boys. The dental age was analyzed in the panoramic x-ray using the classifications y s t e proposed by NollaZ3 (1960) and the bone age in the lateral cephalometric radiographies by the Baccetti et al2 (2002) method. It was observed in the stages of skeletal maturation I and II, the lower canine was in stage 8 in 32% and 34,296 o f the cases, respectively. The lower first premolar was in the stage 7 in the 30,7% of the cases and in stage 8 8n 39,574 of the patients on maturation stages. When the patients was in the stages of skeletal maturation III, IV and v the canine was at the last level of the mineralization - stage 10 of Nolla in 93,8%. 95,8% and 100% of the cases. respectively The same occurred with the premolar in 86,6%, 95,7% and 92,9% of the cases, respectively. The results indicated that the stages more lately of the human growth and development, the level of canine formation and lower first premolar were equally more advanced. Therefore, there is an association between the level of these teeth development and the maturation stage determined by cervical vertebrae in the sample studied.


Subject(s)
Humans , Male , Female , Child , Age Determination by Skeleton , Cervical Vertebrae , Skull/growth & development , Osteogenesis , Radiography, Panoramic
7.
Rev. dent. press ortodon. ortopedi. facial ; 11(2): 29-34, mar.-abr. 2006. ilus, graf
Article in Portuguese | LILACS | ID: lil-431454

ABSTRACT

OBJETIVO: avaliar a freqüência dos sinais e sintomas, dos hábitos parafuncionais e das características oclusais de 80 crianças, pacientes da clínica de Ortodontia Preventiva da Faculdade de Odontologia de Araçatuba - UNESP. METODOLOGIA: o exame clínico constituiu-se de avaliação das características oclusais do paciente e observação da presença de hábitos parafuncionais. As crianças foram submetidas a uma entrevista, supervisionadas pelos pais, cujas perguntas relacionavam-se com os sinais e sintomas da disfunção. RESULTADOS E CONCLUSÕES: concluiu-se que os sinais e sintomas mais freqüentes foram o hábito de ranger os dentes, dores de cabeça e ruídos na ATM. A onicofagia e o bruxismo foram os hábitos parafuncionais mais prevalentes. A freqüência de sinais e sintomas da disfunção temporomandibular pode ser verificada em crianças por meio da entrevista e exame clínico minucioso.


Subject(s)
Humans , Male , Female , Child , Temporomandibular Joint Dysfunction Syndrome/diagnosis , Tooth, Deciduous , Bruxism , Headache , Masticatory Muscles
8.
RGO (Porto Alegre) ; 53(3): 181-185, jul.-set. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: lil-427790

ABSTRACT

Com a finalidade de estimular o atendimento inicial dos pacientes acometidos por traumatismo dento-aveolar pelo clínico geral, os autores apresentam dois casos clínicos envolvendo fraturas coronárias e corono-radiculares, nos quais foram realizados procedimentos de urgência. O adequado atendimento inicial, além de promover conforto para o paciente, removendo a dor, melhora o prognóstico dos casos. Este procedimento pode ser realizado pelo clínico geral, desde que este tenha iniciativa, conhecimentos básicos e habilidade para colocá-los em prática


Subject(s)
Adult , Male , Humans , Emergency Treatment , Tooth Injuries , Tooth Injuries/therapy
SELECTION OF CITATIONS
SEARCH DETAIL